ECG - 1x600 - 170 (640 W)

■ Rated AC voltage 220/230V with a frequency of 50/60Hz;
■ AC supply voltage range 180-250 V;
■ Power factor, not less than 0.96;
■ Preheating of electrodes;
■ Degree of protection against foreign bodies and water - IP20;
■ Electric shock protection class - I;
■ Body material - aluminum;
■ Maximum heating temperature of the case - 70 °C;
■ Permissible ambient temperature - 25 °C - +55 °C;
■ Overall dimensions (Figure 1): 165x125x63 mm;
■ Weight, max. 0.64 kg.
■ The ECR has an output for connecting a lamp indication LED and an alarm output in the form of a non-polar transistor switch. LED current – (2-5) mA. The load current of the switch is not more than 5mA, the maximum switched voltage is not more than 25 V.
■ A green LED is installed on the board to indicate the presence of current in the lamp.
■ 2211 ECGs have a control input shutdown function. When the (9-15)V voltage is applied to the control input, the ECS is switched off.
■ The 2221 ECS has the function of adjusting the current in the lamp in the range of (50 - 100)% of the nominal value when the DC voltage in the range of (0-5)V is applied to the control input.

Attribute
Parameter
Lamp power
500 - 640
Operating current of lamp
5 - 6,5
Warm-up time of lamp electrodes
24-28
Nominal current consumption from mains
2,8
Rated AC voltage
220/230 V(50/60 Hz)
Attribute
Parameter
ECG
EPRA L~220-1x600-22X2-170
Lamp power
600
Lamp current
5