Bpro 180

Bpro 180

■ 60-100% power adjustment (PWM)

■ 94% efficiency at maximum load.

■ Indication of the operating status of the UV lamps/on the housing:

► Blue LED = UV lamp working, ► Red LED = UV lamp not working.

■ Indication of the operating status of the UV lamp / remote lamp

► 5V DC signal ( Max. 5V /DC Max. 5mA = UV lamp working, 0V = UV lamp not working).

► Indication relay (4~5 on = UV lamp working, 5~6 off = UV lamp not working).

■ Rated AC voltage 220/240V with a frequency of 50/60Hz;

■ AC supply voltage range 198-305 V;

■ Power factor, not less than 0.98;

■ Preheating of electrodes;

■ Degree of protection against foreign bodies and water - IP20;

■ Electric shock protection class - I;

■ Body material - aluminum;

■ Maximum heating temperature of the case - 70 °C;

■ Permissible ambient temperature - 10 °C - +50 °C;

■ Weight, not more than 0.43 kg.

■ Protection of electronic circuits.

图片名称

Attribute

Parameter

Lamp power

130-173

Operating current of lamp

2,0-2,1

Warm-up time of lamp electrodes

<10

Nominal current consumption from mains

0,6-0,73

Rated AC voltage

220/240 V(50/60 Hz)

Attribute

Parameter

ECG

Bpro 180

Lamp power

130-173

Lamp current

2,0-2,1